Specifications Common to the Fluid-Trac® Family of liquid level sensors
Range (Gasoline*)
Up to 24 inches (0.6m)
Range(Other)
Up to 32 inches (0.85 m)
Resolution
0.07 inches
Accuracy
+/- 0.125 inches
Operating Temperature
- 40°C to +85°C (--40°F to +185°F)
Storage Temperature
-50°C to +100°C (-58°F to +212°F)
*Note:
Gasoline range is different due to the density of the gasoline vapors. Gasoline vapors are denser as temperature increases which results in the speed of sound being slower.
The Digital Fluid-Trac™ Drum Gauge cannot be used with gasoline.
Specifications Differences to the Fluid-Trac® Family of liquid level sensors
Fluid-Trac® 2 Wire
Fluid-Trac® 3Wire
Digital Fluid-Trac™ Drum Gauge
Output Type
Resistive Emulation
Ratiometric Voltage
Non-Ratiometric Voltage
(0.5 Vdc – 4.5 Vdc)
LCD in gallons
Supply Voltage
N/A
12 V
(10 - 18V)
12 V
(10 - 18V)
24 V
(10 - 30V)
N/A
Output sink Current (Max)
200 mA
20 mA
20 mA
25 mA
N/A
Typical
Application
12 V Fuel Gauge OR
24 V Fuel Gauge
12 V Digital Fuel Gauges
(Electronic Dashes)
Digital Instrumentation OR
Control Modules OR
PLC controllers OR
DAQ systems